<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-03 22-53-45
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 50 dBuV SANDELS
Pilot RDS Phase Difference
4.9 kHz 5.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 68 kHz 12634 12,1656
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,3 dBr 5,21 dBr 5,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 68 kHz MIN: 11 kHz % above 76 kHz: 12,1656 Acquired: 2026.09.03 22.52.42 Total samples: 12634 Equivalent time: 0:10:31 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,9 dBr MIN: 4,3 dBr AVE: 5,21 dBr % above 12,2 dBr: 0,0 Last value: 5,4 dBr (2026.09.03 22.52.41) 22.38 22.40 22.42 22.44 22.46 22.48 22.50 22.52 0 2 4 6 Pm [dBr]